Expo LRV AWD L4-1834cc 1.8L SOHC 16 Valve (1992)
Fig. 22 Connecting Actuator For Operation Check
Fig. 23 Actuator Opearation Check (VAC, VENT1, VENT Solesnoids On)
Fig. 24 Actuator Operation Check (VAC Solenoids Off)
Fig. 25 Actuator Operation Check (VAC Or VENT1, VENT2 Solenoids Off)
1.
Disconnect actuator, then connect battery voltage and an ammeter as shown in, Fig. 22.
2.
Apply 16 inches vacuum to actuator. Ensure actuator is as specified in Fig. 23.
3.
Disconnect wire from terminal 2 and ensure actuator is as specified in Fig. 24.
4.
Disconnect wire on terminal 2 then from terminal 3 one at a time and ensure actuator is as specified in Fig. 25.