[16] Inspection of boost temperature sensor

-

Place boost temperature sensor 16 in glycerin in a container.

-

Raise the glycerin temperature to the specified values and stir the glycerin.

-

Measure the resistance between terminals 1 and 2.

-

If the measured value deviates from the standard value, replace boost temperature sensor.

[17] Inspection of emergency engine stop handle

-

Push emergency engine stop handle 17 all the way.

-

In this step, make sure that stop lever A of the governor is in contact with stopper bolt B.

-

If the stop lever does not contact the stopper bolt, turn nut C until they contact, and tighten nut D to secure it in place.

-

Inner wire E of stop cable F should be taut. If not, make adjustment.

CAUTION:  Be careful not to make the tension of inner wire E too high, since excess tension prevents stop lever A from fully