Closed Throttle Position Switch: Testing and Inspection

Idle Position Switch Circuit

To test the Idle Switch, located on the throttle body, proceed as follows.

COMPONENT TEST

1. Disconnect the idle switch connector.
2. With the throttle closed, use an  Ohm meter and check for continuity between terminal 1 and ground.

Continuity

Should exist.

3. Open the throttle approximately 50%, use an  Ohm meter and check for continuity between terminal 1 and ground.

Continuity

Should not exist.

HARNESS TEST:

1. Disconnect the idle switch connector and turn the key to the ON position.
2. Using a Voltmeter, check the Voltage between the harness connector terminal 1 and ground.

Voltage:

4 - 5 Volts.

3. Turn the key OFF, disconnect the negative battery cable and the ECU Connector.
4. Using an  Ohm meter, check for continuity between ECU harness terminal 6 and idle position switch harness terminal 1.

Continuity

Should exist.

5. Using an  Ohm meter, check for continuity between ECU harness terminal 6 and ground.

Continuity

Should not exist.