Galant L4-1997cc 2.0L SOHC 16 Valve (1993)
Condenser Fan: Testing and Inspection
Fig. 14 Condenser Fan Motor Terminal Identification
1. Disconnect fan motor connector, then apply battery positive voltage to terminal 2 and battery ground to terminal 4, Fig. 14. Motor should operate
smoothly.
2. If results are not as indicated, a new fan motor should be installed.