mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

ECM - Adaptive Memory|Page 3568 > < ECM - Adaptive Memory|Page 3566
Page 1
background image

Idle Speed: Adjustments

NOTE:  Adjustment of idle speed is usually not required. If idle speed is out of specification check and verify the operation of the idle speed control
system.  Refer to COMPUTERS AND CONTROL SYSTEMS.

Fig. 54  Connecting A Tachometer To The Engine Speed Terminal

1. Confirm initial inspection conditions:

a. Engine coolant temperature is 185 - 205°F.
b. Lights, cooling fan and all accessories are OFF.
c. Transaxle is in neutral or park.
d. Steering wheel is in straight-ahead position, (on vehicles with power steering).

2. Check the ignition timing and adjust, if necessary. (Refer to procedure)
3. Connect a tachometer to the engine speed detection connector, Fig. 54. Do not unplug the connector.
4. Start the engine and idle for 2 minutes.
5. Check the engine idle speed. If it is NOT within specifications, check the idle speed control system.

Curb Idle Speed:
700 ± 100 RPM

6. Stop engine and disconnect tachometer. (Leave tachometer connected, if further adjustments are required).

Fig. 55  Idle-Speed Control Servo Connector

IDLE SPEED CONTROL (ISC) SYSTEM

1. Loosen the accelerator cable, so a slight amount of slack is present.
2. Connect a tachometer to the engine speed detection connector.
3. Turn the ignition switch ON, but DO NOT start the engine.
4. Wait at least 15 seconds and check the idle speed control plunger position. The plunger should extend to a fast idle position, then retract after 15

seconds. This is the initial position.

5. Turn the ignition switch OFF and disconnect the electrical connector for the idle speed control servo. This will lock the idle speed control plunger

at the initial position. Fig. 55

6. Loosen the fixed speed adjusting screw (SAS) fully.
7. Start the engine and check that the idle speed is within specifications.

Basic Idle Speed:
700 ± 50 RPM

ECM - Adaptive Memory|Page 3568 > < ECM - Adaptive Memory|Page 3566