Galant L4-1997cc 2.0L SOHC 16 Valve (1993)
Main Relay (Computer/Fuel System): Testing and Inspection
Power Supply Circuit
Engine Control Module Connector--For Pin Applications See Components
Failure of the control relay could interrupt power supply to the fuel pump, injectors and ECU, resulting in start failure.
CAUTION: Use care when connecting jumper wires to the relay. Connecting power or ground to the wrong terminal will damage the relay.
Fig. 1 Control Relay Test