Galant L4-2.0L SOHC (1989)
Instrument Cluster / Carrier: All Technical Service Bulletins
Interior - Separation of Instrument Panel Pad
NO.: TSB-89-23-007
DATE: January, 1989
MODEL: Galant
SUBJECT:
SEPARATION OF INSTRUMENT PANEL PAD AROUND CLOCK OPENING AND ECS CONTROL PANEL OPENING
PURPOSE
The Galant Dash may exhibit a separation of the foam padding from the core base in the areas with an "X" shown. This can be corrected by using a quick
dry type glue to secure the foam to the core.
REPAIR PROCEDURE
^
Remove the clock or ECS control panel.
^
Glue the foam or film attached to the foam to the base as shown below.* Use 3M Quick Fix Adhesive (Cyanoacrylate) part #08155.
After applying the glue you will need to press against the pad for about 30 seconds until the glue sets.
Be careful so as not to get any glue on a visible part of the dash.