Control Reley Test Schematic

Test the continuity of the control relay contacts between terminals 1 - 4 by connecting a 12 volt power source to terminals 6 - 7 and testing for continuity
at terminals 1 - 4.

RELAY CONDITION ...................................................................................................................................................................................  CONTINUITY

NOT ENERGIZED ................................................................................................................................................................ nonconductive (infinite Ohms)
ENERGIZED  ........................................................................................................................................................................................ conductive (0 Ohms)

Test the continuity of the control relay contacts between terminals 2 - 4 by connecting a positive side 12 volt power source to terminal 8 and the negative
side to terminal 6. Check for continuity at terminals 2 - 4.

RELAY CONDITION ...................................................................................................................................................................................  CONTINUITY

NOT ENERGIZED ................................................................................................................................................................ nonconductive (infinite Ohms)
ENERGIZED  ........................................................................................................................................................................................ conductive (0 Ohms)

Relay Test

Test the continuity of the control relay contacts between terminals 1 - 4 by connection a 12 volt power source to terminals 2 - 5 and testing for continuity
at terminals 1 - 4.

RELAY CONDITION ...................................................................................................................................................................................  CONTINUITY

NOT ENERGIZED ................................................................................................................................................................ nonconductive (infinite Ohms)
ENERGIZED  ........................................................................................................................................................................................ conductive (0 Ohms)

If the control relay fails any of the tests, it must be replaced.
   