Galant L4-2.4L (4G69) (2004)
2. Measure the resistance between terminal 6 and ground.
-
The measured value should be 2 Ohms or less.
Q: Does the measured resistance value correspond with this range?
YES: Go to Step 4.
NO: Go to Step 2.
STEP 2. Check the multi-center display unit (middle grade type) connector C-05 for loose, corroded or damaged terminals, or terminals pushed
back in the connector.
Q: Is the multi-center display unit (middle grade type) connector C-05 in good condition?
YES: Go to Step 3.
NO: Repair or replace the connector. Refer to Harness Connector Inspection.