mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 6195 > < Symptom Related Diagnostic Procedures|Page 6193
Page 12
background image

2. Measure the resistance between clock spring connector C-306 (clock spring side) terminals 2 and 3. Operate the right and left remote controlled

radio switches, and check that the table given is satisfied.

NOTE:  When checking the right remote controlled radio switch, do not operate the left remote controlled radio switch.

Q: Is the resistance between terminals 2 and 3 normal?

YES: This malfunction is intermittent. Refer to How to Use Troubleshooting/Inspection Service Points-How to Cope with Intermittent Malfunction.

NO: Go to Step 8.

STEP 8. Measure the resistance at clock spring terminal.

1. Remove the clock spring (Refer to Air Bag Module(s) and Clock Spring).

Symptom Related Diagnostic Procedures|Page 6195 > < Symptom Related Diagnostic Procedures|Page 6193