mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Vacuum Brake Booster Check Valve > < Vacuum Brake Booster|Testing and Inspection|Page 4598
Page 3
background image

1. Use the vacuum pump to measure dimension "A" applying a negative pressure of 66.7 kPa (19.7 inch Hg) to the brake booster.

Standard value (A): 10.28 - 10.52 mm (0.405 - 0.414 inch)

NOTE:  When a negative pressure of 66.7 kPa (19.7 inchHg) is not applied to the brake booster, the push rod protrusion amount (A) should
be 8.78 - 9.02 mm (0.346 - 0.355 inch).

2. If the protrusion amount is not within the standard value range, adjust the push rod length by turning the push rod. Use special tool MB991568

to turn the push rod while holding the rod spline with angle-nose pliers.

Vacuum Brake Booster Check Valve > < Vacuum Brake Booster|Testing and Inspection|Page 4598