mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

A/C - Water Leaks Onto Front Floor Area|Page 5588 > < Evaporator Case|Removal and Installation|Page 5579
Page 1
background image

Evaporator Drain Tube: All Technical Service Bulletins
A/C - Water Leaks Onto Front Floor Area

No.: TSB-08-55-007

DATE: September, 2008

MODEL:
See Below

SUBJECT:
HVAC DRAIN BLOCKAGE, WATER LEAKING ONTO FRONT FLOORBOARDS

This TSB supercedes TSB-04-55-007, issued September, 2004, to add Affected Vehicles, advise to install a grommet seal and add instructions to install
a cabin air filter. It also changes the PARTS INFORMATION and WARRANTY INFORMATION associated with the changes. Revised information is
shown with a <.

PURPOSE

The HVAC drain tube can become blocked by internal foam packing material or by external debris (such as leaves, etc.) entering the front cowl area. If
this occurs, the case may fill up with condensation and overflow onto the passenger's side floorboard. In some case it can overflow into the blower motor.

If water is found to be leaking onto the driver's side floorboard, it may be due to a deteriorated grommet seal between the HVAC unit and the bulkhead <
at the HVAC drain tube. As the vehicle is driven, air flow under the hood forces HVAC drainage back past the grommet and into the vehicle, where it
collects on the driver's side floorboard.

To eliminate these conditions, remove the debris and move the internal foam material away from the drain tube as described in this bulletin and install
the new grommet seal listed in the PARTS INFORMATION SECTION of this bulletin. Always perform both operations when removing the HVAC
assembly.

On certain Endeavor models only, if debris is found in the HVAC case, install a redesigned front deck (cowl) garnish, which will prevent future entry of
debris. Install the new garnish listed in the PARTS INFORMATION section of this bulletin if one was not previously installed for this condition.

AFFECTED VEHICLE(S)

PROCEDURE

1.

Confirm proper blower motor operation.

2.

Clean debris from the evaporator housing drain tube and HVAC case and install a new grommet seal.

a.

Remove the HVAC case and evaporator. Disassemble the HVAC and remove debris from the drain hole area inside. Refer to Group 55
Heating, Air Conditioning & Ventilation in the applicable service manual for removal instruction.

A/C - Water Leaks Onto Front Floor Area|Page 5588 > < Evaporator Case|Removal and Installation|Page 5579