mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

A/C - Water Leaks Onto Front Floor Area|Page 5589 > < A/C - Water Leaks Onto Front Floor Area
Page 2
background image

b.

Inspect the foam inside the HVAC case for drain blockage.

^

If the foam is loose, reaffix it to the case using a small bead of 3M Plastic and Emblem Adhesive (3M 08061) or equivalent.

^

If the foam is blocking the passage for the condensation to reach the drain hole, cut the foam away as necessary in the area indicated
above.

3.

During installation of the cooling unit, replace the grommet seal (listed in the PARTS INFORMATION section of this bulletin) where the drain <
passes through the bulkhead. Insure that the bulkhead and cooling unit surfaces are cleaned of old material prior to replacement.

4.

If debris (leaves, twigs, etc.) was found in the HVAC assembly, install a cabin air filter (listed in the PARTS INFORMATION section of this <
bulletin) into the blower motor housing. Follow the installation instructions included with each filter. Installation instructions are also available on
the MDL from the "parts" page by selecting "parts information, then "Technical Resources," then "Accessory Installation Instructions."

NOTE:

Future replacement of these filters is considered a customer maintenance expense just like any other vehicle filter (oil, air, fuel, etc.).

5.

On Endeavor models only built prior to 7/20/2004. If external debris was found inside the HVAC case, and one has not been installed as part of a
prior repair, install a new, improved front deck (cowl) garnish, to prevent future entry of debris. Later models were built with the garnish (see

A/C - Water Leaks Onto Front Floor Area|Page 5589 > < A/C - Water Leaks Onto Front Floor Area