Refrigerant Temperature Sensor: Testing and Inspection

COOLING TEMPERATURE SWITCH

CAUTION:  Do not heat more than necessary.

1. Dip the metal part of the cooling temperature switch into engine oil and increase the oil temperature using a gas burner or similar.

2. When the oil temperature reaches the standard value, check that voltage is supplied between the terminals.

NOTE:  When the oil temperature is 155 °C (311 °F) or more and there is no continuity, the resistance will not be 2 Ohms or lower until the oil
temperature reduces to 125 °C (257 °F) or less.