Galant L4-2.4L (4G69) (2004)
3. Measure the voltage between terminal 2 and ground.
-
The measured value should be approximately 12 volts (battery positive voltage).
Q: Does the measured voltage correspond with this range?
YES: Replace the multi-center display unit (middle grade type). The multi-center display unit (middle grade type) should work normally.
NO: Go to Step 11.
STEP 11. Check the multi-center display unit (middle grade type) connector C-05 for loose, corroded or damaged terminals, or terminals
pushed back in the connector.
Q: Is multi-center display unit (middle grade type) connector C-05 in good condition?
YES: Go to Step 12.
NO: Repair or replace the connector. Refer to Harness Connector Inspection. The multi-center display unit (middle grade type) should work normally.