mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Hose/Line HVAC > < Coolant Line/Hose|Diagrams|Page 884
Page 2
background image

CAUTION:  Do not let the O-ring get contaminated with grease or engine oil.

Fit an O-ring into the groove of the water inlet pipe and apply water or coolant to the circumference of the O-ring or the inside of the mounting
surface of the water pump or thermostat case for insertion.

>>B<< THERMOSTAT CASE/WATER OUTLET FITTING INSTALLATION 
1. Use a gasket scraper or wire brush to completely eliminate all gasket material on the gasket mounting surface.

2. Apply a bead of the sealant to the cylinder head mating surface of the thermostat case as shown.

Specified Sealant: 3M AAD Part No.8672, 3M AAD Part No.8679/8678 or equivalent

3. Apply sealant to the thread of the thermostat case bolts as shown.

Specified Sealant: 3M AAD Part No.8730, 8731 or equivalent

4. With the sealant still wet (within 15 minutes after the sealant is applied), install the thermostat case. Do not apply the sealant in an area more

than the required.

>>C<< RADIATOR UPPER HOSE CONNECTION 

1. Insert each hose as far as the projection of the water outlet fitting.
2. Align the mating marks on the radiator hose and hose clamp, and then connect the radiator hose.