mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2478 > < Initial Inspection and Diagnostic Overview|Page 2476
Page 43
background image

Front-ECU Power Supply And SWS Communication Circuit Part 2

NOTE:  This troubleshooting procedure requires the use of scan tool MB991958 and SWS monitor kit MB991813. For details on how to use the SWS
monitor, refer to "How to use SWS monitor."  See: Reading and Clearing Diagnostic Trouble Codes/Reading Diagnostic Trouble Codes/How To Use
SWS Monitor

CIRCUIT OPERATION

-

The power supply to the front-ECU is provided by the battery and the ignition switch (IG2).

-

If the power supply system from the battery is defective, the system operates by the power supply from the ignition switch (IG2).

TECHNICAL DESCRIPTION (COMMENT)

It is suspected that the power supply circuit to the front-ECU is defective, or the wiring harness between the SWS monitor kit and the front-ECU or their
connector(s) is damaged. If the battery power supply circuit to the ECU (terminal 5 of the front-ECU) is damaged, also check the power supply circuit
from the ignition switch (IG2) (terminal 22 of the front-ECU), and repair if necessary.

TROUBLESHOOTING HINTS

-

The wiring harness or connectors may have loose, corroded, or damaged terminals, or terminals pushed back in the connector

-

The front-ECU may be defective

-

The ETACS-ECU may be defective

DIAGNOSIS

Required Special Tools:

-

MB991223: Harness Set

-

MB991958: Scan Tool (MUT-III Sub Assembly)
-

MB991824: Vehicle Communication Interface (V.C.I.)

-

MB991827: MUT-III USB Cable

-

MB991910: MUT-III Main Harness A

-

MB991813: SWS Monitor Kit
-

MB991806: SWS Monitor Cartridge

-

MB991812: SWS Monitor Harness (For Column-ECU)

-

MB991822: Probe Harness

STEP 1. Use scan tool MB991958 to select "ECU COMM Check" on the SWS monitor display.

Check the ETACS-ECU.

CAUTION:  To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991958. Connect special tool MB991910 before connecting special tool MB991812. Be sure to connect special tool
MB991806 after turning on special tool MB991824.

Initial Inspection and Diagnostic Overview|Page 2478 > < Initial Inspection and Diagnostic Overview|Page 2476