mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2512 > < Initial Inspection and Diagnostic Overview|Page 2510
Page 77
background image

STEP 5. Check the input signal by using "FUNCTION DIAG." menu of the SWS monitor.

Turn the ignition switch to the "ON" position to check the input signals from the following switches.

1. Operate scan tool MB991958 according to the procedure below to display "OTHER ALARM."

a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f.

Select "BUZZER."

g. Select "OTHER ALARM."

2. Check that normal conditions are displayed for the items described in the table.

NOTE:  If the function switch of the multi center display (middle-grade type) is operated, check that No.43 "BUZZER" is displayed as normal
condition.

Q: Are normal conditions displayed for the "IG SW (IG1)" and "BUZZER"?

Normal conditions are displayed for all the items: Replace the ETACS-ECU. Verify that the multi center display operating sound function
works normally.

Normal condition is not displayed for "IG SW (IG1)": Refer to Inspection Procedure M-2 "ETACS-ECU does not receive any signal from the 

Initial Inspection and Diagnostic Overview|Page 2512 > < Initial Inspection and Diagnostic Overview|Page 2510