STEP 3. Check the input signal (by using the pulse check mode of the monitor).

Check the following switches and input signals:

-

Key reminder switch

-

Door switches

1. Operate scan tool MB991958 according to the procedure below to display "Pulse check."

a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "Pulse Checking."

2. Check if scan tool MB991958 sounds or not.

Q : When the key reminder switch, any door switch is operated, does scan tool MB991958 sound?

Buzzer of scan tool MB991958 sounds normally. :
Replace the ETACS-ECU. The forgotten key prevention function should work normally.

When the ignition key is removed and inserted, scan tool MB991958 does not sound. : Refer to Inspection Procedure N-1 "ETACS-ECU does not
receive any signal from the key reminder switch."

When one of the doors is opened and closed, scan tool MB991958 does not sound : Refer to Inspection Procedure N-3 "ETACS-ECU does not
receive any signal from any of the door switches."

Inspection Procedure D-1

Power Windows: Power windows do not work at all.

NOTE: This troubleshooting procedure requires use of scan tool MB991958 and SWS monitor kit MB991813. For details on how to use the SWS
monitor, refer to Displaying and Reading Trouble Codes/Diagnostic Function/"How to use SWS monitor."

Initial Inspection and Diagnostic Overview|Page 2546 > < Initial Inspection and Diagnostic Overview|Page 2544