STEP 11. Check the wiring harness between front door lock actuator (RH) connector E-05 (terminal 3) and ground.

NOTE: Also check intermediate connector C-12 for loose, corroded, or damaged terminals, or terminals pushed back in the connector. If intermediate
connector C-12 is damaged, repair or replace the connector as described in Harness Connector Inspection.

Q : Is the wiring harness between front door lock actuator (RH) connector E-05 (terminal 3) and ground in good condition?

YES : No action is necessary and testing is complete.

NO : The wiring harness may be damaged or the connector(s) may have loose, corroded or damaged terminals, or terminals pushed back in the
connector. Repair the wiring harness as necessary. If the functions described in "CIRCUIT OPERATION" work normally, the input signal from the
front door lock actuator (RH) should be normal.

STEP 12. Check ETACS-ECU connector C-217 for loose, corroded or damaged terminals, or terminals pushed back in the connector.

Q : Is ETACS-ECU connector C-217 in good condition?

YES : Go to Step 13.

NO : Repair or replace the damaged component(s). Refer to Harness Connector Inspection. If the functions described in "CIRCUIT OPERATION"
work normally, the input signal from the front door lock actuator (RH) should be normal.