Page 430
background image

STEP 7. Check the wiring harness between power window main switch connector E-12 (terminals 5 and 10) and ETACS-ECU connector C-217
(terminals 33 and 34).

NOTE: Also check intermediate connector C-26 for loose, corroded, or damaged terminals, or terminals pushed back in the connector. If intermediate
connector C-26 is damaged, repair or replace the connector as described in Harness Connector Inspection.

Q : Is the wiring harness between power window main switch connector E-12 (terminals 5 and 10) and ETACS-ECU connector C-217 (terminals 33 and
34) in good condition?

YES : Replace the ETACS-ECU. If the central door locking system works normally, input signal from the door lock switch (power window main
switch) should be normal.

NO : The wiring harness may be damaged or the connector(s) may have loose, corroded or damaged terminals, or terminals pushed back in the
connector. Repair the wiring harness as necessary. If the central door locking system works normally, input signal from the door lock switch (power
window main switch) should be normal.

STEP 8. Check power window sub switch connector E-04 for loose, corroded or damaged terminals, or terminals pushed back in the connector.

Q : Is power window sub switch connector E-04 in good condition?

YES : Go to Step 9.

NO : Repair or replace the damaged component(s). Refer to Harness Connector Inspection. If the central door locking system works normally, input
signal from the door lock switch (front power window sub switch) should be normal.

Initial Inspection and Diagnostic Overview|Page 2865 > < Initial Inspection and Diagnostic Overview|Page 2863