5. Measure the resistance between joint connector (3) terminal 4 and combination meter connector terminal 14.
OK: 2 ohms or less
CAUTION: Strictly observe the specified wiring harness repair procedure. For details Service Precautions/Vehicle Damage Warnings.
Q: Do all the resistances measure 2 ohms or less?
YES: If all the resistances measure 2 ohms or less, go to Step 6.
NO: If either of the resistances measures more than 2 ohms or all the resistances measure more than 2 ohms, repair the wiring harness between
joint connector (3) and the combination meter connector, and then go to Step 2.
STEP 6. Check the terminator resistor inside the combination meter. Measure the resistance at combination meter connector C-101.
CAUTION: A digital multimeter should be used. For details Service Precautions/Vehicle Damage Warnings.
1. Disconnect combination meter C-101, and measure the resistance at the component side of combination meter connector C-101.