6. When the abnormal condition is displayed, press the OK button and go to the calibration screen. If the cancel button is pressed the screen

returns to step (4).

7. Unload the weight, check the seat installation condition and carry out the friction removal in step (2) again, and press the OK button. When the

execution dialog is displayed, press the OK button again to execute the calibration.

8. The calibration has been completed when the screen as shown in the illustration is displayed. Press the OK button to return to the screen of

step (4), and carry out the same procedure.