Page 3
background image

4. For accuracy check 30 kg (66 pounds), slide the seat to the front end, and put the 30 kg (66 pounds) weight on the center of the seat cushion.

Then, carry out the friction removal in step (2) and press the OK button to execute accuracy check.

NOTE:  If there is not the 30 kg (66 pounds) weight, load a square thing of 30 to 40 kg (66 to 88 pounds) instead of the weight. At this time,
operate the arrow button of weight input part on MUT-III to input the loaded weight value.

5. If the tolerance level between the sensor output and the input value is within 4.9 kg (11 pounds), the screen for the accuracy check completion

is displayed, and if more than 4.9 kg (11 pounds), the screen for abnormal condition is displayed.

NOTE:  When the screen for the accuracy check of 0 kg (0 pound) is displayed, go to step (9). If the abnormal condition is displayed, check
the seat installation condition. If the seat is improperly installed, install it properly and carry out the operation in step (4) again. 