Battery: Service and Repair

BATTERY CHARGING

WARNING:  When batteries are being charged, an explosive gas forms beneath the cover of each cell. Do not smoke near batteries on charge
or which have recently been charged. Do not break live circuits at the terminals of the batteries on charge. A spark will occur where the live
circuit is broken. Keep all open flames away from the battery.

Battery electrolyte temperature may temporarily be allowed to rise to 55 °C (131 °F). Increase of electrolyte temperature above 55 °C (131 °F) is
harmful to the battery, causing deformation of battery cell, decrease in life of battery, etc.

CHARGE RATE

If the test indicator is white, the battery should be charged as outlined. When the dot appears or when maximum charge shown is reached, charging
should be stopped.