2. Measure the resistance between terminal 2 and ground.

Q: Is the resistance less than 2 Ohms?

YES: Go to Step 8.

NO: Go to Step 6.

STEP 6. Check immobilizer-ECU connector C-124 for loose, corroded or damaged terminals, or terminals pushed back in the connector.

Q: Is immobilizer-ECU connector C-124 in good condition?

YES: Go to Step 7.

NO: Repair or replace the component(s). Refer to Harness Connector Inspection. Confirm that scan tool MB991958 communicates normally.

STEP 7. Check the wiring harness between immobilizer-ECU connector C-124 (terminal 2) and ground.