Galant ES L4-2350cc 2.4L SOHC MFI (1997)
Thermostat: Testing and Inspection
-
Check that valve closes tightly at room temperature.
-
Check for defects or damage.
-
Check for rust or encrustation on valve, remove if any.
-
Immerse thermostat in container of water. Stir to raise water temperature and check that the thermostat valve opening temperature and the
temperature with valve fully open. Valve lift over 8.5 mm (0.33 inch) are at the standard value.
-
The standard values are:
-
Valve opening temperature: 82° C (180° F)
-
Full opening temperature: 95° C (203° F)
NOTE: Measure valve height when fully closed. Calculate lift by measuring the height when fully open.