Fan Control Module Check
Fan Control Module Check
1. Remove condenser fan motor connector.
2. Start the engine and run it at idle.
3. Turn the A/C switch to ON and maintain the coolant temperature at 80°C (176°F) or less.
4. When measuring the voltage between the fan control module-side connector terminals, check that the value changes repeatedly as indicated by (1)
- (3) below.
1) 0.0 V
2) <2.4L ENGINE - 1999 models> 9.6 ± 2.6 V
<2.4L ENGINE - 2000 models> 8.2 ± 2.6 V
<3.0L ENGINE - 1999 models> 6.8 ± 2.6 V
<3.0L ENGINE - 2000 models> 8.2 ± 2.6 V
3) Battery voltage ± 2.6 V
5. If the voltage does not repeatedly change as indicated, replace the radiator fan motor and the fan control module assembly.