Galant LS V6-3.0L SOHC (1999)
Idle Air Control Motor: Oscilloscope Patterns and Waveforms
IDLE AIR CONTROL MOTOR (STEPPER MOTOR)
Required Special Tool:
MB991709: Test Harness
Measurement Method
1. Disconnect the idle air control motor connector, and connect the test harness special tool (MB991709) in between. (All terminals should be
connected.)
2. Connect the analyzer special patterns pickup to the idle air control motor connector terminal 1 terminal 3 terminal 4 and terminal 6 respectively.
Alternate method (Test harness not available)
1. Connect the analyzer special patterns pickup to PCM terminals 14, 15, 28 and 29.
Standard Wave Pattern
Observation conditions
Standard Wave Pattern
Wave Pattern Observation Points
1. Check that the standard wave pattern appears when the idle air control motor is operating.