mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Knock Sensor > < Diagram Information and Instructions|Page 708
Page 1
background image

Intake Air Temperature Sensor: Testing and Inspection

INTAKE AIR TEMPERATURE SENSOR CHECK

1. Disconnect the volume air flow sensor connectors.

2. Measure resistance between terminals 5 and 6.

Standard value: 
2.3 - 3.0 k Ohm [at 20° C (68° F)]
0.30 - 0.42 Ohm [at 80° C (176° F)]

If not within specifications, replace the volume air flow sensor.

3. Measure resistance while heating the sensor using a hair dryer.

Normal condition:

4. If resistance does not decrease as heat increases, replace the volume air flow sensor assembly.

Knock Sensor > < Diagram Information and Instructions|Page 708