mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 2888 > < Component Tests and General Diagnostics
Page 2
background image

1. Remove the EGR valve.

2. Connect special tool MB991658 to the EGR valve.

3. Connect the battery positive (+) terminal to terminal No. 2.

CAUTION:  Connecting battery voltage to the EGR valve for a long time could damage the coil.

4. Connect terminals 1 and 3 to the negative (-) terminal of the battery, in order to test whether the stepper motor vibrates (with a slight shudder),

indicating that the stepper motor is operating.

5. Connect the battery positive (+) terminal to terminal No. 5.

CAUTION:  Connecting battery voltage to the EGR valve for a long time could damage the coil.

6. Connect terminals 4 and 6 to the negative (-) terminal of the battery, in order to test whether the stepper motor vibrates (with a slight shudder),

indicating that the stepper motor is operating.

7. If vibrations can be felt as a result of the test, the stepper motor is determined to be normal.
8. Using a new gasket, install the EGR valve by tightening its mounting bolts to the specified torque.

Tightening torque: 24 ± 3 N.m (212 ± 27 in-1b)