mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 2889 > < Component Tests and General Diagnostics|Page 2887
Page 1
background image

EGR Valve: Oscilloscope Patterns and Waveforms

EGR VALVE (STEPPER MOTOR)

Required Special Tools:

-

MB991658: Test Harness

-

MB992110: Power Plant ECU Check Harness

Measurement Method

1. Disconnect the EGR valve connector, and connect the test harness special tool (MB991658) between the separated connector (All terminals should

be connected).

2. Connect the oscilloscope probe to the EGR valve connector terminal No. 1, terminal No. 3, terminal No. 4, terminal No. 6 respectively.

Alternate method

1. Disconnect all ECM connectors. Connect the check harness special tool (MB992110 between the separated connectors.

2. Connect the oscilloscope probe to check harness terminal No. 31, No. 32, No. 47 and No. 48.

Component Tests and General Diagnostics|Page 2889 > < Component Tests and General Diagnostics|Page 2887