Lancer L4-2.4L (4B12) (2009)
CAUTION
Avoid adhesion of engine oil or grease to the O-ring.
Fit the O-ring in the water pump inlet pipe groove, wet the O-ring circumference or the pipe mounting area inner wall, and then insert the O-ring.
]]H[[ RADIATOR LOWER HOSE/RADIATOR UPPER HOSE INSTALLATION
1. Insert radiator hose as far as the projection of the water inlet fitting, water outlet fitting or radiator.
2. Align the mating marks on the radiator hose and hose clamp, and then connect the radiator hose.