mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

ACD Bleeding|Page 3571 > < ACD Bleeding
Page 1
background image

Fluid - Transfer Case: Service and Repair
ACD Control Fluid Check

ACD CONTROL FLUID CHECK

[WHEN THE SCAN TOOL IS NOT USED]

1. Remove the trunk room side trim lid on the right of the trunk room.
2. If the vehicle has been run, leave it for 90 min. or more in an ordinary temperature {10 - 30° C (50 - 86° F)} to allow the accumulator internal

pressure to drop.

NOTE: If the ambient temperature is 10° C (50° F) or less, allow more time to leave the vehicle to stand idle.

3. Check that the oil reservoir fluid level is in between MAX and MIN.
4. If the fluid level is not in between MAX and MIN, fill the specified fluid.

Brand name: Dia Queen ATF SP III

5. Install the trunk room side trim lid.

[WHEN THE SCAN TOOL IS USED]

1. Remove the trunk room side trim lid on the right of the trunk room.

CAUTION: 
Turn the ignition switch to the "LOCK (OFF)" position before connecting or disconnecting the scan tool.

2. Set the scan tool to the 16-pin diagnosis connector.
3. Turn the ignition switch to the ON position.
4. Using the scan tool, forcibly activate the hydraulic unit (item No. 03) to reduce the pressure inside the accumulator. 

NOTE:
^

With the forced activation (oil level check mode), the hydraulic unit direction valve is operated 20 seconds to right and left, and then the
operation is cancelled automatically. Also, using the clear key on the scan tool, the activation can be forcibly cancelled.

^

When the functions are suspended by the fail-safe function, the hydraulic unit cannot be forcibly activated.

5. Check that the oil reservoir fluid level is in between MAX and MIN.
6. If the fluid level is not in between MAX and MIN, fill the specified fluid.

Brand name: Dia Queen ATF SP III

7. Install the trunk room side trim lid.

ACD Bleeding|Page 3571 > < ACD Bleeding