Lancer L4-2.4L SOHC (2005)
NO: Replace the power window relay. Verify that the power windows work normally.
STEP 5. Check the fusible link (5) line of power supply circuit to the power window relay. Measure the voltage at power window relay
connector C-224.
1. Disconnect power window relay connector C-224 and measure the voltage available at the junction block side of the connector.
2. Measure the voltage between terminal 5 and ground.
-
The voltage should equal approximately 12 volts (battery positive voltage).
Q: Is the measured voltage approximately 12 volts (battery positive voltage)?
YES: Go to Step 7.
NO: Go to Step 6.