mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Component Locations|Page 2743 > < Component Locations|Page 2741
Page 2
background image

CAUTION: 
-

Be very careful when connecting the jumper wire; incorrect connection can damage the heated oxygen sensor.

-

Be careful the heater is broken when voltage of beyond 12 volts is applied to the heated oxygen sensor heater.

NOTE:  If the sufficiently high temperature [of approximate 400°C (752°F) or more] is not reached although the heated oxygen sensor is normal,
the output voltage would be possibly low although the rich air/fuel ratio. Therefore, if the output voltage is low, use jumper wires to connect the
terminal No.1 and the terminal No.3 of the heated oxygen sensor with a (+) terminal and (-) terminal of 12 volts power supply respectively, then
check again.

3. If the output voltage is not within the standard value, replace the heated oxygen sensor.

NOTE:  For removal and installation of the heated oxygen sensor, refer to Exhaust Pipe and Main Muffler <EXCEPT FOR CALIFORNIA>, refer
to Exhaust Pipe and Main Muffler VEHICLES FOR CALIFORNIA.

<Heated oxygen sensor (front)> 

1. Using the scan tool MB991958, observe HO2S reading. If values are unsatisfactory, or if Scan tool is not available, use the following procedure:

1. Disconnect the heated oxygen sensor connector and connect special tool MB991658 to the connector on the heated oxygen sensor side.
2. Make sure that there is continuity [4.5 - 8.0 ohms at 20°C (68°F)] between terminal No.3 and terminal No.4 on the heated oxygen sensor

connector.

3. If there is no continuity, replace the heated oxygen sensor.
4. Warm up the engine until engine coolant is 80°C (176°F) or higher.

5. Perform a revving for 5 minutes or more with the engine speed of 4,500 r/min.
6. Connect a digital voltage meter between terminal No.1 and terminal No.2.

Component Locations|Page 2743 > < Component Locations|Page 2741