Lancer LS L4-2.0L SOHC (2002)
1. Connect a R-134a refrigerant recovery/recycling/charging station (A) to the high-pressure service port (8) and the low-pressure service port (C), as
shown, following the equipment manufacturer's instructions.
2. Evacuate the system.
3. Add the same amount of new refrigerant oil to the system that was removed during recovery.
4. Charge the system with the specified amount of R-134a refrigerant. Do not overcharge the system; the compressor will be damaged.
Select the appropriate units of measure for your refrigerant charging station.
5. Check for refrigerant leaks.
6. Check for system performance.