mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Transfer Case > < Mechanical Specifications|Page 4152
Page 1
background image

Transmission Temperature Sensor/Switch: Testing and Inspection

A/T FLUID TEMPERATURE SENSOR CONTINUITY CHECK 

1. Remove the A/T fluid temperature sensor.
2. Measure the resistance between terminals No.1 and No.2 of the A/T control solenoid valve assembly connector.

Standard value 

3. If the A/T fluid temperature sensor resistance is not consistent with the fluid temperature replace A/T fluid temperature sensor.

NOTE:  The N range indicator light on the combination meter flashes when the temperature reaches approximately 125°C (257°F) or higher,
and then stops flashing when the temperature drops below approximately 115°C (238°F).

Transfer Case > < Mechanical Specifications|Page 4152