mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Procedures|Page 3460 > < Procedures|Page 3458
Page 3
background image

NOTE: Please execute after making a tire and a steering wheel straight.

12. The display should show "Completed." Press "OK" button.
13. Turn the ignition switch to "LOCK" (oft) position, and then turn the ignition switch ON again.
14. Select the relevant system from the menu.
15. Select "ABS/ASC/ASTC/WSS" from the system list under "System select", and press "OK" button.
16. Select "Special function" under "ABS/ASC/ASTC/WSS".
17. Select "Sensor calibration" under "Special function".
18. Select "SAS calibration" under "Sensor calibration", and press "OK" button.
19. The screen displays "SAS calibration: The selected command will be executed. Are you sure? Caution: Confirm the execution conditions." Then

press "OK" button.

20. "Executed: The command was executed." will be shown. Then press "OK" button.
21. Select "Diagnostic trouble code" under "ABS/ASC/ASTC/WSS". If the diagnostic trouble code "C2205 SAS internal failure (past trouble)" is set,

clear it.

22. Learning neutral point complete
23. Turn the ignition switch to "LOCK" (OFF) position and then disconnect the scan tool.

[When the steering wheel sensor is replaced] 

1. Carry out steps 1 to 21 of the steering wheel sensor calibration for when the ASC-ECU is replaced.
2. Select the relevant system from the menu.
3. Select "ACD/AYC" from the system list in "System select", and press "OK" button.
4. Select "Special function" under "ACD/AYC".
5. Select "Sensor calibration" under "Special function".

NOTE: If the steering angle sensor neutral point has been learned, the display will show "If SAS needs re-calibration, execute SAS calibration
after executing SAS initialization". If yes, press "OK" button.

6. As "SAS Calibration" is selected under "Sensor calibration", press "OK" button.

NOTE: At this time, if the steering angle sensor neutral point has been learned, the display will show "Do you want to start? Note This operation
will dear DTCs ". Then, press "OK" button.

7. The display should show "Completed." Press "OK" button.
8. Press the OK button.
9. The display should show "SAS Calibration: Do you want to start?". Then press the OK button.

NOTE: Please execute after making a tire and a steering wheel straight.

10. The display should show "Completed." Press "OK" button.
11. Turn the ignition switch to "LOCK" (oft) position, and then turn the ignition switch ON again.
12. Select the relevant system from the menu.
13. Select "ACD/AYC" from the system list under "System select", and press "OK" button.
14. Select "Special function" under "ACD/AYC".
15. Select "Sensor calibration" under "Special function".
16. Select "SAS calibration" under "Sensor calibration", and press "OK" button.
17. The screen displays "SAS calibration: The selected command will be executed. Are you sure? Caution: Confirm the execution conditions." Then

press "OK" button.

18. "Executed: The command was executed." will be shown. Then press "OK" button.
19. Select "Diagnostic trouble code" under "ACD/AYC". If the diagnostic trouble code "U1428 G and Yaw Rate Sensor Data Error (past trouble)" is

set, clear it.

20. Learning neutral point complete
21. Turn the ignition switch to "LOCK" (OFF) position and then disconnect the scan tool.

Procedures|Page 3460 > < Procedures|Page 3458