5. Connect battery cable from battery negative post to starter motor body.
6. Adjust the rheostat until the battery voltage shown by the voltmeter is 11.5 V (for the direct-drive type) or 11 V (for the reduction-drive type).
7. Confirm that the maximum amperage is within the specifications and that the starter motor turns smoothly and freely.

Current:

max. 60 Amps (Direct drive type)
max. 90 Amps (Reduction drive type)

Magnetic Switch Return Test

Fig. 9  Testing Magnetic Switch Return Function

1. Disconnect field coil wire from M-terminal of magnetic switch.
2. Connect a 12 V battery between M-terminal and body.

CAUTION:  This test must be performed quickly (in less than 10 Seconds) to prevent coil from burning.

3. Pull pinion out and release. If pinion quickly returns to its original position, everything is in order. If it doesn't, replace magnetic switch.

CAUTION:  Take care to not pinch your fingers when pulling the pinion out.