Ignition Relay: Testing and Inspection

Power Supply Circuit

Failure of the control relay could interrupt power supply to the fuel pump, injectors and ECU, resulting in start failure. 

CAUTION: Use caution when connecting jumper wires to the relay. If the polarity is incorrectly connected, the relay will be damaged.

COMPONENT TEST

Fig. 1 Relay Test

1. Supply 12 vdc to relay terminals 8 (-) and 10 (+). Using a voltmeter, check for voltage between terminals 4 (+) and 8 (-) and between terminals 5

(+) and 8 (-). Refer to Fig. 1.

Voltage

12 vdc