mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Ignition Relay > < Component Tests and General Diagnostics|Page 4149
Page 2
background image

Wave Pattern Observation Points

Point : Condition of wave pattern build-up section and maximum voltage (Refer to abnormal wave pattern examples 1 and 2.)

Examples Of Abnormal Wave Patterns

-

Example 1
Wave pattern during engine cranking.

Cause of problem

Open-circuit in ignition primary circuit.

Wave pattern characteristics

Top-right part of the build-up section can not be seen, and voltage value is approximately 2V too low.

-

Example 2
Wave pattern during engine cranking

Cause of problem

Malfunction in ignition power transistor

Wave pattern characteristics

Power voltage results when the ignition power transistor is ON.

Ignition Relay > < Component Tests and General Diagnostics|Page 4149