mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Starter Brush > < Armature Testing|Page 5187
Page 1
background image

Starter Bearing: Testing and Inspection

Commutator

1. Place the armature on a pair of V-blocks, and check the runout with a dial indicator.

Standard value: 0.05 mm (0.0020 in.)
Limit: 0.1 mm (0.0040 in.)

Commutator

2. Check the commutator outer diameter.

Standard value: 32.0 mm (1.260 in.)
Limit: 31.0 mm (1.220 in.)

Commutator

3. Check the undercut depth between segments.

Standard value: 0.5 mm (0.020 in.)