Mirage Sedan DE L4-1468cc 1.5L SOHC MFI (1997)
Alternator Relay: Testing and Inspection
Generator Relay Continuity Check
1. Remove the generator relay from the relay box inside the engine compartment.
2. Set a ohmmeter and check that there is continuity when the (+) terminal of the tester is connected to terminal 4 of the generator relay and the (-)
terminal is connected to terminal 2.
3. Next, check that there is no continuity when the (+) terminal is connected to terminal 2 and the (-) terminal is connected to terminal 4.
4. If the continuity checks in steps 2 and 3 show a defect, replace the generator relay.