mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Manifold Pressure/Vacuum Sensor > < Diagram Information and Instructions|Page 477
Page 1
background image

Intake Air Temperature Sensor: Testing and Inspection

1. Disconnect the intake air temperature sensor connector.
2. Measure resistance between terminals 1 and 2.

Standard value:
2.3 - 3.0 KOhms [at 20°C (68°F)]
0.30 - 0.42 KOhms  [at 80°C (176°F)]
 

3. Remove the intake air temperature sensor.

4. Measure resistance while heating the sensor using a hair dryer.

Normal condition: 

5. If the value deviates from the standard value or the resistance remains unchanged, replace the intake air temperature sensor.
6. Install the intake air temperature sensor and tighten it to the specified torque.

Tightening torque: 12 - 15 Nm (9 - 11 ft.lbs.) 

Manifold Pressure/Vacuum Sensor > < Diagram Information and Instructions|Page 477