mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 2379 > < Symptom Related Diagnostic Procedures|Page 2377
Page 2
background image

Point A: Presence or absence of induced electromotive force from the motor turning. (Refer to the abnormal wave pattern.)

Point B: Height of coil reverse electromotive force

Examples of Abnormal Wave Pattern

-

Example 1

Cause of problem
Motor is malfunctioning. (Motor is not operating.)

Wave pattern characteristics
Induced electromotive force from the motor turning does not appear.

-

Example 2

Cause of problem
Open circuit in the line between the IAC motor and the ECM.

Wave pattern characteristics
Current is not supplied to the motor coil on the open circuit side. voltage does not drop to 0 V.) Furthermore, the induced electromotive force
waveform at the normal side is slightly different from the normal waveform.

Resistance Test

IDLE AIR CONTROL MOTOR (STEPPER MOTOR) CHECK