Intake Air Temperature Sensor: Testing and Inspection

INTAKE AIR TEMPERATURE SENSOR CHECK

1. Disconnect the volume air flow sensor connectors.
2. Measure resistance between terminals 5 and 6.

Standard value:
2.3 - 3.0 kOhms [at 20 °C (68 °F)]
0.30- 0.42 kOhms [at 80 °C (176 °F)]

3. Measure resistance while heating the sensor using a hair dryer.

Normal condition:

4. If resistance does not decrease as heat increases the resistance remains unchanged, replace the volume air flow sensor assembly.

Manifold Pressure/Vacuum Sensor > < Diagram Information and Instructions|Page 2620