mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 3056 > < Symptom Related Diagnostic Procedures
Page 1
background image

Idle Speed/Throttle Actuator - Electronic: Component Tests and General Diagnostics

Oscilloscope Testing

IDLE AIR CONTROL (STEPPER) MOTOR

Measurement Method

1. Disconnect the IAC motor connector, and connect the special tool (test harness: MD998463) in between.
2. Connect the analyzer special patterns pickup to the IAC motor-side connector terminal 1 (red clip of special tool), terminal 3 (blue clip), terminal 4

(black clip) and terminal 6 (yellow clip) respectively.

Alternate Method Test harness not available)

1. Connect the analyzer special patterns pickup to ECM terminal 4, connection terminal 5, connection terminal 17, and connection terminal 18

respectively.

Standard Wave Pattern

Observation conditions

Standard wave pattern

Wave Pattern Observation Points

Check that the standard wave pattern appears when the IAC motor is operating.

Symptom Related Diagnostic Procedures|Page 3056 > < Symptom Related Diagnostic Procedures