If there is a continuity at both, the diode is short circuited, so replace the rectifier.

3. Check the diode trio by connecting an ohmmeter to both ends of each diode and check the continuity of the three diodes.

If there is a continuity at both ends, or if there is no continuity, the diode is damaged so replace the rectifier.

ROTOR CHECK

Rotor

1. Check the continuity between the rotor coil slip rings, and replace the rotor if the resistance value is not at the standard value.

Standard value: 3 - 5 ohms

Rotor

2. Check the continuity between the slip ring and core, and if there is continuity, replace the rotor.

STATOR CHECK

Stator

1. Check the continuity between the coil leads, and it there is continuity, replace the stator.

Component Tests and General Diagnostics|Page 4364 > < Component Tests and General Diagnostics