Montero V6-3.8L SOHC (2005)
Seat Heater: Testing and Inspection
Seat Cushion Heater Check
SEAT CUSHION HEATER CHECK
Measure the resistance between terminals.
Standard value: At room temperature 20° C (68° F)
Between terminals 2 and 3: Approximately 4.2 Ohms ± 10%
Between terminals 1 and 3: 4.0 Ohms ± 10%